Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Design and Testing of Augmented Reality-Based Fluorescence Imaging Goggle for Intraoperative Imaging-Guided Surgery

Authors
Lee, Seung HyunQuan, Yu HuaKim, Min SubKwon, Ki HyeokChoi, Byeong HyeonKim, Hyun KooKim, Beop-Min
Issue Date
6월-2021
Publisher
MDPI
Keywords
augmented reality; fluorescence image; neuro-navigation; smart goggle
Citation
DIAGNOSTICS, v.11, no.6
Indexed
SCIE
SCOPUS
Journal Title
DIAGNOSTICS
Volume
11
Number
6
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/127971
DOI
10.3390/diagnostics11060927
ISSN
2075-4418
Abstract
The different pathways between the position of a near-infrared camera and the user's eye limit the use of existing near-infrared fluorescence imaging systems for tumor margin assessments. By utilizing an optical system that precisely matches the near-infrared fluorescence image and the optical path of visible light, we developed an augmented reality (AR)-based fluorescence imaging system that provides users with a fluorescence image that matches the real-field, without requiring any additional algorithms. Commercial smart glasses, dichroic beam splitters, mirrors, and custom near-infrared cameras were employed to develop the proposed system, and each mount was designed and utilized. After its performance was assessed in the laboratory, preclinical experiments involving tumor detection and lung lobectomy in mice and rabbits by using indocyanine green (ICG) were conducted. The results showed that the proposed system provided a stable image of fluorescence that matched the actual site. In addition, preclinical experiments confirmed that the proposed system could be used to detect tumors using ICG and evaluate lung lobectomies. The AR-based intraoperative smart goggle system could detect fluorescence images for tumor margin assessments in animal models, without disrupting the surgical workflow in an operating room. Additionally, it was confirmed that, even when the system itself was distorted when worn, the fluorescence image consistently matched the actual site.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyun Koo photo

Kim, Hyun Koo
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE