Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effect of novel double treatment on the properties of CdTe solar cells

Authors
Kim, SangsuSong, Ju-YoungKim, DeokHong, JinkiCho, Ick JoonKim, Yong HyubJeong, Jae-UkYoon, Mee SunAhn, Sung-JaChung, Woong-KiNam, Taek-KeunCho, Shinhaeng
Issue Date
11월-2021
Publisher
ELSEVIER
Keywords
Cadmium sulfide; Cadmium telluride; Cl activation; Freon treatment; Solar cell; Time of flight
Citation
ENERGY REPORTS, v.7, pp.1396 - 1403
Indexed
SCIE
SCOPUS
Journal Title
ENERGY REPORTS
Volume
7
Start Page
1396
End Page
1403
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/135881
DOI
10.1016/j.egyr.2021.02.070
ISSN
2352-4847
Abstract
In this study, the effect of Cl activation treatment on performance indicators of CdS/CdTe solar cells was investigated. We improved the performance of CdTe solar cells by applying a novel double treatment method that combines the CdCl2 dipping treatment and Freon (difluoro chloromethane) treatment methods that were previously studied. Conventional CdCl2 methanol dipping treatment (CdCl2 dipping treatment), Freon gas treatment that includes chlorine (Freon treatment), and CdCl2 dipping treatment + Freon treatment (double treatment) were performed, and the efficiencies, open circuit voltage (VOC), and short circuit current (JSC) for all three processes were observed. Although the efficiencies of the CdCl2 dipping treatment and Freon treatment were similar, there was a trade-off between the VOC and JSC in both processes. The double treatment sample shows an efficiency of 14.3%, which was higher than that of a single-treated sample. To investigate the characteristic change of each part of the solar cell, an equivalent circuit model in which the device was divided into a main junction and a back contact was used. In addition to electrical measurements, secondary ion mass spectroscopy (SIMS) and time of flight (TOF) analysis were performed. Through TOF measurement, drift mobility values for three treatment samples were calculated to be 1.1 cm(2)/Vs, 1.8 cm(2)/Vs, and 1.9 cm(2)/Vs, respectively. With TOF measurement, it was proved that the double treatment had a significant influence on the efficiency of the sample. (C) 2021 Published by Elsevier Ltd.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Semiconductor Physics in Division of Display and Semiconductor Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Jin Ki photo

Hong, Jin Ki
과학기술대학 (디스플레이·반도체물리학부 반도체물리전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE