Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluating the Accuracy (trueness and Precision) of Interim Crowns Manufactured Using Digital Light Processing According to Post-curing Time: an in Vitro Study

Authors
Lee, B.-I.You, S.-G.You, S.-M.Kim, D.-Y.Kim, J.-H.
Issue Date
4월-2021
Publisher
Korean Academy of Prosthodontic
Keywords
Digital light processing; Interim crown; Post-curing time; Precision; Trueness
Citation
Journal of Advanced Prosthodontics, v.13, no.2, pp.89 - 99
Indexed
SCIE
SCOPUS
KCI
Journal Title
Journal of Advanced Prosthodontics
Volume
13
Number
2
Start Page
89
End Page
99
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/137859
DOI
10.4047/jap.2021.13.2.89
ISSN
2005-7806
Abstract
Purpose. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to postcuring time. Materials and Methods. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute postcuring interim crown (20-MPCI), and 30-minute post-curing interim crown (30MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). Results. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces ( P <.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. Conclusion. Interim crowns with 10-minute post-curing showed high accuracy. [J Adv Prosthodont 2021;13:89-99] © 2021 The Korean Academy of Prosthodontics
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE