Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Ultra-low-dose intraoperative X-ray imager for minimally invasive surgery: a pilot imaging studyopen access

Authors
Park, HaewookHan, Kook NamChoi, Byeong HyeonYoon, HyunsukAn, Hyun JoonLee, Jae SungKim, Hyun Koo
Issue Date
4월-2022
Publisher
AME PUBL CO
Keywords
Ultra-low-dose; X-ray imaging; minimally invasive surgery; lung cancer
Citation
TRANSLATIONAL LUNG CANCER RESEARCH, v.11, no.4, pp.588 - 599
Indexed
SCIE
SCOPUS
Journal Title
TRANSLATIONAL LUNG CANCER RESEARCH
Volume
11
Number
4
Start Page
588
End Page
599
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/142148
DOI
10.21037/tlcr-21-909
ISSN
2226-4477
Abstract
Background: With advances in surgical technology, thoracic surgeons have widely adopted minimally invasive limited-resection techniques to preserve normal tissues. However, it remains difficult to achieve in situ localization of invisible pulmonary nodules during surgery. Therefore, we proposed an in situ ultra-low-dose X-ray imaging device for intraoperative pulmonary nodule localization during minimally invasive surgeries. Methods: The proposed device features a hand-held type and consists of a carbon nanotube-based X-ray source and an intraoral dental sensor. In a preclinical study, we created pseudo pulmonary nodules using ex vivo pig lungs. Subsequently, its clinical feasibility was evaluated using ex vivo lung cancer specimens from patients with cancer who had undergone minimally invasive surgery. Results: Using the proposed device, we successfully differentiated normal and abnormal tissues from X-ray images of resected lung specimens. In addition, our proposed device only yielded an average radiation dose of 90.9 nGy for a single acquisition of X-ray images and demonstrated excellent temperature stability under consecutive X-ray irradiations. The radiation exposure of our proposed device (0.1 +/- 0.0006 mu Sv/h) was significantly lower than that of conventional C-arm fluoroscopy (41.5 +/- 51.8 mu Sv/h). In both preclinical and clinical studies, the margin of nodule shadows was clearly visualized using the proposed device. Conclusions: The proposed device substantially reduced radiation exposure to staff and patients and may allow in situ localization of pulmonary nodules. Our proposed device clearly revealed the margins of lung nodules with radiocontrast injection and showed the potential to identify solid nodules without the use of radiocontrast agents.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyun Koo photo

Kim, Hyun Koo
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE