A simple reagent-less approach using electrical discharge as a substitution for chelating agent in addressing genomic assay inhibition by divalent cations

Authors
Jin, HyowonYoon, YeominLiles, Mark R.Chua, BeeleeSon, Ahjeong
Issue Date
7-11월-2020
Publisher
ROYAL SOC CHEMISTRY
Citation
ANALYST, v.145, no.21, pp.6846 - 6858
Indexed
SCIE
SCOPUS
Journal Title
ANALYST
Volume
145
Number
21
Start Page
6846
End Page
6858
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/51824
DOI
10.1039/d0an01666g
ISSN
0003-2654
Abstract
Electrical discharge treatment was shown to be a viable substitution for chelating agent in genomic assays. Divalent cation Mg2+ inhibits the performance of DNA hybridization based genomic assays by binding to the DNA and disrupting DNA hybridization. Until now, chelating agents such as ethylenediaminetetraacetic acid (EDTA) was the only option to address the presence of Mg2+ in samples. However, EDTA is a well-known environmental contaminant. In this work, we successfully employed electrical discharge instead of EDTA to render Mg2+ insipid. Its preliminary efficacy was first observed via circular dichroism (CD) and zeta potential analyses. After electrical discharge treatment, the reduction in CD shift at 280 nm was significant for samples with 10(-3) and 10(-8) M Mg2+. The zeta potential of Mg2+ laden samples were also restored from -4.71 +/- 1.38 to -20.59 +/- 6.37 mV after electrical discharge treatment. Both CD shift and change in zeta potential suggested that 2 min of electrical discharge treatment could prevent Mg2+ from binding to DNA. The complete efficacy of electrical discharge treatment was demonstrated with the performance recovery (within similar to 15% of the control) of a genomic assay variant (NanoGene assay) while analyzing Mg2+ laden samples (10(-5)-10(-3) M). Assuming 10 million samples are analyzed annually, the proposed electrical discharge treatment (similar to 50 mW per sample) would allow us to trade environmental contamination by similar to 50 kg of hazardous EDTA with a single 250 W STC (standard test conditions) solar panel.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chua, Beelee photo

Chua, Beelee
공과대학 (전기전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE