Evaluation based on performance and failure of PV system in 10 years field-aged 1 MW PV power plant

Authors
Oh, WonwookChoi, HoonjooSeo, Kun WonKim, DaesungKim, So-YeonLee, Hae-SeokHwang, HeonKim, Donghwan
Issue Date
11월-2020
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Citation
MICROELECTRONICS RELIABILITY, v.114
Indexed
SCIE
SCOPUS
Journal Title
MICROELECTRONICS RELIABILITY
Volume
114
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/52057
DOI
10.1016/j.microrel.2020.113763
ISSN
0026-2714
Abstract
PV (Photovoltaic) power systems have been rapidly installed and spreading worldwide in recent years. And there is a belief that the PV power plant will operate stably for more than 25 years. However, the PV modules have an unexpected failure. In this paper, we diagnosed a 10-year-old power plant using drone with infra-red (IR) camera, current-voltage (I-V) and electroluminescence (EL) measurement. The approximately 1 MW plant, consisting of two different PV modules, 200 W and 220 W, showed various failure modes. 59% PV modules failure caused an output loss, and an inverter with a serious loss is expected to degrade more than its annual degradation rate in PV strings above 40%. As a result, the power loss was quantitatively estimated to hot spot, bypass diode failure and degradation rate, and the capacity of the current PV system was evaluated at 88.3% and 93.2%.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School of Energy and Environment (KU-KIST GREEN SCHOOL) > Department of Energy and Environment > 1. Journal Articles
College of Engineering > Department of Materials Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, Dong hwan photo

KIM, Dong hwan
공과대학 (신소재공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE