Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Quantitative analysis of radiation dosage and image quality between digital breast tomosynthesis (DBT) with two-dimensional synthetic mammography and full-field digital mammography (FFDM)

Authors
Choi, YoonmiWoo, Ok-heeShin, Hye-sunCho, Kyu RanSeo, Bo KyoungChoi, Ga-Young
Issue Date
5월-2019
Publisher
ELSEVIER SCIENCE INC
Keywords
Digital breast tomosynthesis; Full-field digital mammography; 2-Dimensional synthetic mammography; Radimetrics; Image quality; Radiation dose
Citation
CLINICAL IMAGING, v.55, pp.12 - 17
Indexed
SCIE
SCOPUS
Journal Title
CLINICAL IMAGING
Volume
55
Start Page
12
End Page
17
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/65923
DOI
10.1016/j.clinimag.2019.01.014
ISSN
0899-7071
Abstract
Purpose: Currently in diagnostic setting for breast cancer, FFDM and DBT are performed conjunctively. However, performing two imaging modalities may increase radiation exposure by double. Two-dimensional reconstructed images created from DBT with 2DSM, has a potential to replace conventional FFDM in concerning both radiation dosage and image quality. With increasing concerns for individual radiation exposure, studies analyzing radiation dosage in breast imaging modalities are needed. This study compared radiation dosage and image quality between DBT + 2DSM versus FFDM. Methods and materials: 374 patients (mean age 52 years) who underwent both DBT and FFDM were retrospectively reviewed. Radiation dosage data were obtained by radiation dosage scoring and monitoring program Radimetrics (Bayer HealthCare, Whippany, NJ). Entrance dose and mean glandular doses in each breast were obtained for both modalities. To compare image quality of DBT + 2DSM and FFDM, a 5-point scoring system for lesion clarity was assessed. The parameters of radiation dosage (entrance dose, mean glandular dose) and image quality (lesion clarity scoring) were compared. Results: For entrance dose, DBT had lower mean dosage (14.8 mGy) compared with FFDM (21.8 mGy, p-value < 0.0001). Mean glandular doses for both breasts were lower in DBT (Left 1.74, Right 2.1) compared with FFDM (Left 2.85, Right 2.74, p-value < 0.0001). Lesion clarity score was higher in DBT with 2DSM (mean score 4.03) compared with FFDM (3.82, p-value < 0.0001). Conclusion: DBT showed lower radiation entrance dose and mean glandular doses to both breasts compared with FFDM. DBT + 2DSM had better image quality than FFDM, suggesting that DBT with 2DSM has potential as an alternative to FFDM.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Kyu Ran photo

Cho, Kyu Ran
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE