Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of collimator on imaging performance of Yttrium-90 Bremsstrahlung photons: Monte Carlo simulation

Authors
Kim, MinhoBae, Jae KeonHong, Bong HwanKim, Kyeong MinLee, Wonho
Issue Date
4월-2019
Publisher
KOREAN NUCLEAR SOC
Keywords
Yttrium-90; Bremsstrahlung imaging; Collimator; Energy window; Gamma camera
Citation
NUCLEAR ENGINEERING AND TECHNOLOGY, v.51, no.2, pp.539 - 545
Indexed
SCIE
SCOPUS
KCI
Journal Title
NUCLEAR ENGINEERING AND TECHNOLOGY
Volume
51
Number
2
Start Page
539
End Page
545
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/66446
DOI
10.1016/j.net.2018.11.007
ISSN
1738-5733
Abstract
Yttrium-90 is a useful therapeutic radioisotope for tumor treatment because of its high-energy-emitting beta rays. However, it has been difficult to select appropriate collimators and main energy windows for Y-90 Bremsstrahlung imaging using gamma cameras because of the broad energy spectra of Y-90. We used a Monte Carlo simulation to investigate the effects of collimator selection and energy windows on Y-90 Bremsstrahlung imaging. We considered both MELP and HE collimators. Various phantoms were employed in the simulation to determine the main energy window using primary-to-scatter ratios (PSRs). Imaging performance was evaluated using spatial resolution indices, imaging counts, scatter fractions, and contrast-to-noise ratios. Collimator choice slightly affected energy spectrum shapes and improved PSRs. The HE collimator performed better than the MELP collimator on all imaging performance indices (except for imaging count). We observed minor differences in SR and SF values for the HE collimator among the five simulated energy windows. The combination of an HE collimator and improved-PSR energy window produced the best CNR value. In conclusion, appropriate collimator selection is an important component of Bremsstrahlung Y-90 photon imaging and main energy window determination. We found HE collimators to be more appropriate for improving the imaging performance of Bremsstrahlung Y-90 photons. (C) 2018 Korean Nuclear Society, Published by Elsevier Korea LLC.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won ho photo

Lee, Won ho
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE