Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The clock drawing test: A systematic review and meta-analysis of diagnostic accuracy

Authors
Park, JinKyungJeong, EunHyeSeomun, GyeongAe
Issue Date
Dec-2018
Publisher
WILEY
Keywords
clock drawing test; cognitive impairment; dementia; diagnostic accuracy; literature review; meta-analysis; sensitivity; specificity; systematic review
Citation
JOURNAL OF ADVANCED NURSING, v.74, no.12, pp.2742 - 2754
Indexed
SCIE
SSCI
SCOPUS
Journal Title
JOURNAL OF ADVANCED NURSING
Volume
74
Number
12
Start Page
2742
End Page
2754
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/71312
DOI
10.1111/jan.13810
ISSN
0309-2402
Abstract
Aim The aim of this study was to evaluate the accuracy of the clock drawing test and to compare its scoring methods. Background Dementia refers to a symptom where an adult demonstrates memory disorder and cognitive impairment. Early diagnosis of dementia is very important for medication management and prognosis. The clock drawing test is one of the most used cognitive screening tools for dementia. However, due to its scoring system, the accuracy of the clock drawing test remains a topic of debate. Design A systematic review with meta-analysis following Cochrane's methods and the guidelines of the Agency for Healthcare Research and Quality. Data sources A literature search was carried out in the OVID-MEDLINE, OVID-EMBASE and OVID-PsycINFO databases (27 October 2015). Review method The quality assessment of diagnostic accuracy studies (QUADAS-2) tool was employed for this review. We used hierarchical regression models to pool the values of diagnostic accuracy in a random effects model. Results A total of 18 studies with 5,531 participants were identified for this review. Fifteen of these studies were included for meta-analysis according to each scoring system. The pooled sensitivity and specificity of the clock drawing test using the Shulman system were 82% and 75.7% respectively. In the Sunderland system, these were 72.6% and 87.9% respectively. Conclusions The findings indicate that the accuracy of the clock drawing test using the Shulman system was the most studied and highly sensitive. After gaining a better understanding of the clock drawing test through this study, we recommend it for widespread use in the diagnosis of dementia.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Nursing > Department of Nursing > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher SEOMUN, Gyeong Ae photo

SEOMUN, Gyeong Ae
College of Nursing (Department of Nursing)
Read more

Altmetrics

Total Views & Downloads

BROWSE