Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

Authors
Jang, YeonSim, Ji-YoungPark, Jong-KyoungKim, Woong-ChulKim, Hae-YoungKim, Ji-Hwan
Issue Date
10월-2018
Publisher
KOREAN ACAD PROSTHODONTICS
Keywords
Marginal and internal fit; Intra oral scanner; Digital light processing; 3D printing model; PolyJet
Citation
JOURNAL OF ADVANCED PROSTHODONTICS, v.10, no.5, pp.367 - 373
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF ADVANCED PROSTHODONTICS
Volume
10
Number
5
Start Page
367
End Page
373
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/72549
DOI
10.4047/jap.2018.10.5.367
ISSN
2005-7806
Abstract
PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (alpha=.05). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<120 mu m).
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE