Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Enhanced resolution of a surface plasmon resonance sensor detecting C-reactive protein via a bimetallic waveguide-coupled mode approach

Authors
Lee, Hwa-SeubSeong, Tae-YeonKim, Won MokKim, InhoHwang, Gyu-WeonLee, Wook SeongLee, Kyeong-Seok
Issue Date
1-8월-2018
Publisher
ELSEVIER SCIENCE SA
Keywords
Surface plasmon resonance sensor; Bimetallic waveguide-coupled surface; plasmon resonance; C-reactive protein; Resolution enhancement
Citation
SENSORS AND ACTUATORS B-CHEMICAL, v.266, pp.311 - 317
Indexed
SCIE
SCOPUS
Journal Title
SENSORS AND ACTUATORS B-CHEMICAL
Volume
266
Start Page
311
End Page
317
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/73814
DOI
10.1016/j.snb.2018.03.136
ISSN
0925-4005
Abstract
Extensive efforts have been devoted to improving the resolution of surface plasmon resonance (SPR) sensors in the detection of trace levels of biomolecules considered essential for the early diagnosis of disease. As part of these efforts, we previously developed a bimetallic waveguide-coupled surface plasmon resonance (Bi-WCSPR) sensor configuration designed to dramatically reduce the linewidth of the SPR curve while preserving a moderate local field decay length, thereby addressing the resolution issue. In this study, we systematically quantified the enhanced resolution in Bi-WCSPR sensors used to detect C-reactive protein (CRP), a widely accepted biomarker of inflammation in cardiovascular disease. Individual SPR sensorgrams were measured at several CRP concentrations in both the intensity and angular interrogation modes, confirming that the Bi-WCSPR configuration with a high Ag-to-Au ratio provided a figure-of-merit (FOM) that was 2.53 times higher than that of conventional Au sensors and a limit-of-detection (LOD) that was an order of magnitude lower than the cut-off level for CRP. It was found that when using the Bi-WCSPR configurations, the resolution enhancement in the intensity interrogation mode becomes more evident as the CRP concentrations is lowered to the cut-off level. (C) 2018 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Materials Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher SEONG, TAE YEON photo

SEONG, TAE YEON
공과대학 (신소재공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE