IGZO-based electrolyte-gated field-effect transistor for in situ biological sensing platform

Authors
Chae, Myung-SicPark, Ju HyunSon, Hyun WooHwang, Kyo SeonKim, Tae Geun
Issue Date
1-Jun-2018
Publisher
ELSEVIER SCIENCE SA
Keywords
Igzo; Oxide semiconductor; EGFET; Biosensor
Citation
SENSORS AND ACTUATORS B-CHEMICAL, v.262, pp.876 - 883
Indexed
SCIE
SCOPUS
Journal Title
SENSORS AND ACTUATORS B-CHEMICAL
Volume
262
Start Page
876
End Page
883
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/74976
DOI
10.1016/j.snb.2018.02.090
ISSN
0925-4005
Abstract
An amorphous indium gallium zinc oxide (IGZO)-based electrolyte-gated field-effect transistor (IGZO-EGFET) was fabricated and its feasibility as a biological sensing platform was evaluated. Herein, a 50-nm-thick IGZO thin film deposited via radio-frequency sputtering was utilized as both the active channel and biological interface of the device. The fabricated IGZO-EGFET operated by inducing a gate voltage directly through the liquid electrolyte at a low bias range ( similar to+1.5 V) with a subthreshold swing of 185 mV dec(-1). The high uniformity of electrical characteristics for the devices were confirmed with 11.4% chip-to-chip deviation by measuring the threshold voltages (V-th), and the shift of Vth was employed as a major parameter to determine the biological interactions. In order to assess IGZO-EGFETs as a biosensing platform, first, pH sensing was conducted with and without amino-silanization on the IGZO surface. The amine-modified device showed steeper slope between Vth shifts and pH variations (68.5 mV pH(-1)) than that (32.7 mV pH(-1)) of the bare IGZO-EGFET. Subsequently, IGZO-EGFETs immobilized with a monoclonal antibody were employed for the in situ detection of alpha-synuclein (alpha S) proteins in concentration ranges from 10 fg mL(-1) to 1 ng mL(-1). The results showed that IGZO-EGFETs are suitable for the specific recognition of analytes with a linear relationship of 9.35 mV dec(-1) between Vth shifts and alpha S concentrations in a logarithmic scale, verifying its applicability as a sensing device for biological interactions. (C) 2018 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Tae geun photo

Kim, Tae geun
College of Engineering (School of Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE