Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

세 가지 방식으로 제작한 하악 총의치의 중합 전후에 따른 인공치아 위치 3차원 분석Three-dimensional analysis of artificial teeth position according to three type complete mandibular denture before and after polymerization

Other Titles
Three-dimensional analysis of artificial teeth position according to three type complete mandibular denture before and after polymerization
Authors
김웅철박진영김동연김원수이광영정일도배소연김지환
Issue Date
2018
Publisher
대한치과기공학회
Keywords
Complete mandibular denture; Polymerization; Three-dimensional analysis; Bar-type glass fiber mesh; Shrinkage
Citation
대한치과기공학회지, v.40, no.4, pp.217 - 224
Indexed
KCI
Journal Title
대한치과기공학회지
Volume
40
Number
4
Start Page
217
End Page
224
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/79603
DOI
10.14347/kadt.2018.40.4.217
ISSN
1229-3954
Abstract
Purpose: The aim of this study was to evaluate accuracy of three type complete mandibular denture of before and after polymerization. Methods: Mandibular edentulous model was selected as the master model. 15 study models were made by Type Ⅳ stone. Wax complete mandibular dentures were produced by the denture base and artificial teeth. Before and after curing, STL files were obtained using a blue scanner. By superimposing the digitized complete mandibular denture data(after curing) with the CAD-reference(before curing) three-dimensionally, visual fit-discrepancies were drawn by calculating the root mean square (RMS) and visualized on a color-difference map. Each calculated RMS-value was statistically analyzed by 1-way analysis of variance(ANOVA) (α = .05). Results: Mean(SD) RMS-values was OM group 88.98(6.10)㎛, BM group 82.35(13.46)㎛, BDM group 77.83(9.46)㎛. The results of the 1-way ANOVA showed no statistically significant differences in the RMS values of the Three groups for the material (P > .241). Conclusion : Deformation of artificial teeth position was observed in all groups after resin polymerization. But the values, all group were within the clinically acceptable range. The values of BDM group showed the least deformation than the other two groups.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE