Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Pure-Tone Average Methods for Estimation of Hearing Loss Caused by Environmental Exposure to Lead and Cadmium: Does the Pure-Tone Average Method Which Uses Low-Frequency Ranges Underestimate the Actual Hearing Loss Caused by Environmental Lead and Cadmium Exposure?

Authors
Huh, Da-AnChoi, Yun-HeeJi, Myung SunMoon, Kyong WhanYoon, Seok J.Sohn, Jong-Ryeul
Issue Date
2018
Publisher
KARGER
Keywords
Cadmium; Hearing; Lead; Pure-tone average
Citation
AUDIOLOGY AND NEURO-OTOLOGY, v.23, no.5, pp.259 - 269
Indexed
SCIE
SCOPUS
Journal Title
AUDIOLOGY AND NEURO-OTOLOGY
Volume
23
Number
5
Start Page
259
End Page
269
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/81063
DOI
10.1159/000494049
ISSN
1420-3030
Abstract
Previous studies have reported that exposure to lead and cadmium can damage the inner ear receptor, which perceives high-frequency sounds. However, few studies have used the pure-tone average (PTA), including high-frequency ranges, for the estimation of hearing loss caused by lead and cadmium exposure. We estimated hearing loss using the PTA test, in low-frequency, speech frequency, and high-frequency ranges and compared the differences in the results using 3 PTA calculation methods. We analyzed the data of 2,387 participants, between the ages of 19 and 85 years, that were obtained from the Korea National Health and Nutrition Examination Survey (KNHANES) of 2010-2012. A dose-response relationship between hearing loss and heavy metal exposure was observed in the high-frequency method after adjustment for confounding factors. When using the high-frequency PTA, it was found that doubling of the levels of lead and cadmium in the blood was associated with a 1.88(95% CI 1.11-3.17) and 1.89-fold (95% CI 1.02-3.50) increase in the OR for hearing loss. In the case of the low-frequency and speech frequency PTA, however, there were no significant relationships between hearing loss and the concentrations of lead and cadmium in the blood. The outcomes of the present study suggest that the estimation of hearing loss caused by environmental exposure to lead and cadmium is affected by the frequencies used in the PTA calculation. (C) 2018 The Author(s) Published by S. Karger AG, Basel
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Kyong Whan photo

Moon, Kyong Whan
College of Health Sciences (School of Health and Environmental Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE