Biochemical-immunological hybrid biosensor based on two-dimensional chromatography for on-site sepsis diagnosis
- Authors
- Kim, Seung-Wan; Cho, Il-Hoon; Lim, Guei-Sam; Park, Gi-Na; Paek, Se-Hwan
- Issue Date
- 15-12월-2017
- Publisher
- ELSEVIER ADVANCED TECHNOLOGY
- Keywords
- Heterogeneous analytes; Multiplexed biosensing; Two-dimensional chromatography; Smartphone detector; Rapid sepsis diagnosis
- Citation
- BIOSENSORS & BIOELECTRONICS, v.98, pp.7 - 14
- Indexed
- SCIE
SCOPUS
- Journal Title
- BIOSENSORS & BIOELECTRONICS
- Volume
- 98
- Start Page
- 7
- End Page
- 14
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/81173
- DOI
- 10.1016/j.bios.2017.06.032
- ISSN
- 0956-5663
- Abstract
- A hybrid-biosensor system that can simultaneously fulfill the immunoassay for protein markers (e.g., C-reactive protein (CRP) and procalcitonin (PCT)) and the enzyme assay for metabolic substances (e.g., lactate) in the same sepsis-based sample has been devised. Such a challenge was pursued through the installation of an enzyme-reaction zone on the signal pad of the typical immuno-strip for the rapid two-dimensional (2-D)-chromatography test. To minimize the mutual interference in the hybrid assays, a pre-determined membrane site was etched in a pattern and mounted with a biochemical-reaction pad, thereby allowing a loaded sample to enter and then stay in the pad for a colored-signal production over the course of an immunoassay. By employing such a constructed system, a serum sample was analyzed according to the vertical direction flowing along the strip, which supplied lactate to the biochemical-reaction zone and then protein markers to the immunological-binding area that was pre-coated with capture antibodies. Thereafter, the enzyme-signal tracers for the immunoassay and the substrate solution were sequentially furnished using a horizontal path for the tracing of the immune complexes that were formed with CRP or PCT. The color signal that was produced from each assay was detected at a pre-determined time and quantified on a smartphone-based detector. Under the optimal conditions, the dynamic ranges for the analytes covered the respective clinical ranges, and the total coefficient of variation was between 8.6% and 13.3%. The hybrid biosensor further showed a high correlation (R-2 > 0.95) with the reference systems for the target markers.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Science and Technology > Department of Biotechnology and Bioinformatics > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.