Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

First-Order Mathematical Correlation Between Damping and Resonance Frequency Evaluating the Bone-Implant Interface

Authors
Kwon, Taek-KaKim, Hae-YoungYang, Jae-HoWikesjo, Ulf M. E.Lee, JaebumKoo, Ki-TaeYeo, In-Sung
Issue Date
Sep-2016
Publisher
QUINTESSENCE PUBLISHING CO INC
Keywords
damping; implant stability; insertion torque; Periotest; resonance frequency analysis
Citation
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, v.31, no.5, pp.1008 - 1015
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
Volume
31
Number
5
Start Page
1008
End Page
1015
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/87615
DOI
10.11607/jomi.4468
ISSN
0882-2786
Abstract
Purpose: Various advanced technologies have been designed to estimate dental implant stability, including insertion torque, implant damping using the Periotest, and resonance frequency analysis expressed in implant stability quotient units. This study aimed to establish the relationship between the estimates for these three techniques. Materials and Methods: Bovine cortical bone blocks were trimmed to square shapes of precisely controlled thickness and density. Thereafter, 4-mm-diameter x 10-mm-long implants were placed in the bone blocks using 30-, 45-, and 60-Ncm insertion torques. Implant damping and resonance frequency analysis were conducted at four angles for each implant. Spearman correlation coefficients were calculated to examine the relationship between insertion torque, resonance frequency analysis, and implant damping measured values. Results: Resonance frequency analysis and implant damping estimates exhibited a strong inverse correlation (r = -0.98, P<.001). A linear equation was formulated: Periotest value = 15.54 + (-0.26 x implant stability quotient). Implant damping and resonance frequency estimates revealed a weak correlation with insertion torque (P<.05). Conclusion: This study mathematically defined a linear correlation between implant damping and resonance frequency estimates, thereby providing a guide for clinicians when deciding the loading time for dental implants using the implant damping or resonance frequency estimates.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hae Young photo

Kim, Hae Young
College of Health Sciences (Division of Health Policy and Management)
Read more

Altmetrics

Total Views & Downloads

BROWSE