Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Constructability and heat exchange efficiency of large diameter cast-in-place energy piles with various configurations of heat exchange pipe

Authors
Park, SangwooSung, ChihunJung, KyoungsikSohn, ByonghuChauchois, AlexisChoi, Hangseok
Issue Date
5-11월-2015
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Closed-loop vertical ground heat exchanger; Energy pile; In-situ thermal response test; Constructability of energy pile; Relative heat exchange efficiency
Citation
APPLIED THERMAL ENGINEERING, v.90, pp.1061 - 1071
Indexed
SCIE
SCOPUS
Journal Title
APPLIED THERMAL ENGINEERING
Volume
90
Start Page
1061
End Page
1071
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/91924
DOI
10.1016/j.applthermaleng.2015.05.044
ISSN
1359-4311
Abstract
A new ground heat exchanger (GHEX) assembled in a ground source heat pump (GSHP) system has been devised, which is equipped in a structural pile, and thus called an "energy pile". In this study, six large-diameter cast-in-place energy piles that encased various types of heat exchange pipes (i.e., three parallel U-types with 5 pairs, 8 pairs and 10 pairs; two coil-types with 200 mm coil pitch and 500 mm coil pitch; and S-type) were constructed in a test bed, and the constructability of each type of the energy pile was compared. Additionally, a 30 m-deep closed-loop vertical GHEX was separately constructed to compare the thermal performance and economic feasibility with the energy piles. A series of in-situ thermal response tests (TRTs) was performed to evaluate the relative heat exchange efficiency of each energy pile according to the various heat exchange pipe configurations. The relative heat exchange efficiency obtained in the cast-in-place energy piles and the down-sized 30 m-deep closed-loop vertical GHEX was normalized by the pile length (or borehole length) and the total heat exchange pipe length. The result from the in-situ tests indicates that the longer the heat exchange pipe installed, the higher heat exchange efficiency per pile length. However, in the case of tight layouts of the heat exchange pipe, thermal interference occurs between adjacent pipe loops, which decreases heat exchange efficiency. Economic feasibility of the energy piles was evaluated, considering the material and installation costs for assembling the heat exchange pipe with consideration of the heat exchange efficiency. It is concluded that the coil-type cast-in-place energy pile can achieve sufficient capacity for heat exchange, compared with the closed-loop vertical GHEX. (C) 2015 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, HANG SEOK photo

CHOI, HANG SEOK
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE