Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Sampling Polyhexamethylene Guanidine Aerosols Using Eosin Y-coated Glass Beads

Authors
Choi, Sang-HyunPark, Seon-KyungKang, Hyun-JoongLee, KyuhongKwon, Jung-Hwan
Issue Date
Jul-2015
Publisher
WILEY-V C H VERLAG GMBH
Keywords
Passive samplers; Exposure assessment; Colorimetry; Indoor air
Citation
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.36, no.7, pp.1819 - 1823
Indexed
SCIE
SCOPUS
KCI
Journal Title
BULLETIN OF THE KOREAN CHEMICAL SOCIETY
Volume
36
Number
7
Start Page
1819
End Page
1823
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/93114
DOI
10.1002/bkcs.10345
ISSN
0253-2964
Abstract
Fatalities caused by the use of polyhexamethylene guanidine (PHMG), a general-purpose chemical germicide used as a humidifier disinfectant in Korea, have raised concerns about exposure to biocide aerosols in indoor environments. A sampler capable of accumulating PHMG from aqueous aerosols was developed as an alternative to low-volume air samplers. This sampler was prepared by placing glass beads coated with 2-(2,4,5,7-tetrabromo-6-oxido-3-oxo-3H-xanthen-9-yl)benzoate (Eosin Y) in a custom-made plastic holder. Passive sampling rates, measured in a bench-top exposure chamber at two different aqueous PHMG aerosol generation rates, were found to be independent of the experimental conditions. This suggests that the capacity of the sampler to accumulate the PHMG aerosol was sufficient for the sampling duration tested. However, the passive sampling rate was 7.6x10(-6)m(3)/h for the sampler area of 22cm(2). This rate is lower than the typical human breathing rate and inadequate for quantitative instrumental analyses at low concentrations in indoor air. A 30-fold enhancement of the sampling rate was achieved by forced convection using a commercial battery-operated fan at 2000rpm. With this accelerated sampling rate, the sampler could be used to monitor time-integrated concentrations of PHMG aerosols in the air.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Sciences and Biotechnology > Division of Environmental Science and Ecological Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kwon, Jung Hwan photo

Kwon, Jung Hwan
College of Life Sciences and Biotechnology (Division of Environmental Science and Ecological Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE