Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Rapid Detection of Mycobacterium tuberculosis Using a Novel Ultrafast Chip-Type Real-Time Polymerase Chain Reaction System

Authors
Lee, Seung HyeunKim, Sung-WooLee, SehyunKim, EunSubKim, Duck-JoongPark, SohyunLee, Eun JooLee, Sang YeubLee, Ji SungLim, Chae SeungKim, Won-KiIn, Kwang Ho
Issue Date
Nov-2014
Publisher
ELSEVIER SCIENCE BV
Citation
CHEST, v.146, no.5, pp.1319 - 1326
Indexed
SCIE
SCOPUS
Journal Title
CHEST
Volume
146
Number
5
Start Page
1319
End Page
1326
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/96839
DOI
10.1378/chest.14-0626
ISSN
0012-3692
Abstract
BACKGROUND: NBS LabChip G2-3 is a novel, ultrafast, chip-type portable real-time polymerase chain reaction (PCR) system. We evaluated the clinical usefulness of this system in detecting pulmonary TB and assessed its diagnostic performance compared with a conventional tube-type PCR system. METHODS: A total of 247 sputum samples were collected from patients suspected of having pulmonary TB. Aft er the decontamination process, these samples were examined by fluorescence staining for acid-fast bacilli, cultures with both solid and liquid media, and real-time PCR with the NBS LabChip and a conventional tube-type system. The diagnostic accuracy of the NBS LabChip system and the agreement between the two assays were evaluated. RESULTS: Considering mycobacterial culture results as a gold standard, the overall sensitivity and specificity of the NBS LabChip was 83.8% (95% CI, 73.8%-91.1%) and 94.0% (95% CI, 89.3%-97.1%), respectively. For the detection of TB from the smear-positive samples, the sensitivity and specificity of the NBS LabChip was 96.0% (95% CI, 86.3%-99.5%) and 83.3% (95% CI, 72.3%-95.7%), respectively. For the smear-negative samples, the sensitivity and specificity of the NBS LabChip was 63.3% (95% CI, 43.9%-80.1%) and 95.0% (95% CI, 90.4%-97.8%), respectively. There were no significant differences in the sensitivity and specificity between the NBS LabChip and a conventional tube-type system, although the NBS LabChip shortened the PCR time (27 min for 45 cycles). CONCLUSIONS: The NBS LabChip G2-3 system has potential as an ultrafast, cost-effective diagnostic tool for pulmonary TB with high sensitivity and specificity.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sang Yeub photo

Lee, Sang Yeub
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE