Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Implementation of a revolute-joint-based asymmetric Schonflies motion haptic device with redundant actuation

Authors
Kim, Sung MokYi, Byung-JuCheong, JoonoKim, Min GunKim, Wheekuk
Issue Date
Apr-2018
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Schonflies motion; Haptic device; Kinematic analysis; Kinematic characteristic; Singularity analysis; Gravity compensation; Inertia compensation
Citation
MECHATRONICS, v.50, pp.87 - 103
Indexed
SCIE
SCOPUS
Journal Title
MECHATRONICS
Volume
50
Start Page
87
End Page
103
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/76216
DOI
10.1016/j.mechatronics.2017.12.004
ISSN
0957-4158
Abstract
In this work, a revolute joint-based asymmetric Schonflies motion (SM) haptic device with 4-Degree-of-Freedom (DOF) force feedback capability is developed. The SM haptic device is composed of a redundantly actuated parallel sub-module which has translational 3-DOF output motion, a pantograph limb which takes the role of providing 1-DOF rotational output motion, and a revolute joint allowing the relative motion between them. All five DC motors without gearhead are placed on the ground by employing proper parallel transmission linkages for power transmission. The large singularity-free workspace and the improved kinematic characteristics are secured by redundantly actuating the 3-DOF sub-module. Thus, the SM haptic device has excellent features such as the unlimited 1-DOF rotational output motion, minimal friction, minimal inertia, and large dexterous workspace. Mobility analysis, kinematic modeling, singularity analysis, optimal design, and linear inertia modeling of the SM haptic device are conducted. Then a prototype with two operational modes such as gravity compensation and linear inertia compensation modes is implemented. Through friction measurements, motion tests for gravity and/or linear inertia compensation modes, and virtual wall experiments, it is confirmed that the prototype possesses minimal friction as well as good gravity and linear inertia compensation performances sufficient for the high-quality haptic device applications such as medical training, robot-assisted surgery, etc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Control and Instrumentation Engineering > 1. Journal Articles
College of Science and Technology > Department of Electro-Mechanical Systems Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cheong, Joo no photo

Cheong, Joo no
Department of Control and Instrumentation Engineering
Read more

Altmetrics

Total Views & Downloads

BROWSE